DY 125U MCCBs
DY 125U MCCBs

DY 125U MCCBs

DY 125U MCCBs Specification

  • Phase
  • Single & Three Phase
  • Rated Short Circuit Making Current
  • 12.5kA to 18.75kA
  • Mechanical Life
  • Up to 10,000 operations
  • Breaking Capacity
  • 10kA/15kA
  • Rated Short Circuit Breaking Current
  • 10kA to 15kA
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • DIN Rail or Fixed Mounting
  • Function
  • Overload & Short Circuit Protection
  • Poles Number
  • 1P, 2P, 3P, 4P
  • Rated Voltage
  • AC 400V
  • Rated Current
  • 10A to 125A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • C, D Curves
  • Temperature Protection
  • Yes
  • Weight
  • Approx. 650g-800g (varies by model)
  • Color
  • Grey/Black
  • Standards Compliance
  • IEC 60947-2
  • Electrical Life
  • Up to 5,000 operations
  • IP Rating
  • IP20
  • Terminal Connection
  • Screw Type / Busbar
  • Trip Type
  • Thermal Magnetic
  • Rated Insulation Voltage
  • 800V
  • Operating Temperature
  • -5°C to +40°C
 

DY 125U MCCBs Trade Information

  • FOB Port
  • JAIPUR, NEEMRANA, ALWAR
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque
  • Supply Ability
  • 10 Per Week
  • Delivery Time
  • 5-7 Week
  • Main Domestic Market
  • All India
  • Certifications
  • GST, GEM
 

About DY 125U MCCBs


Conforms to IS/IEC 60947-2, IEC 60947-2 & EN 60947-2

Range : 16A to 125A, 2P/3P/4P

Ics= 100% of Icu

High Electrical & mechanical life

Thermal magnetic release

No load-Line bias

ON-TRIP-OFF indication

Suitable for isolation 

Common SS Enclosure for 3P & 4P



Advanced Protection and Reliability

Designed to safeguard electrical circuits, the DY 125U MCCB delivers dependable overload and short circuit protection. With breaking capacities up to 15kA, it ensures electrical systems operate safely against unexpected faults, helping prevent costly downtime and equipment damage.


Flexible Installation and Wide Application

This MCCB supports both DIN rail and fixed mounting options, accommodating diverse installation setups across industries. It comes in variants of 1P, 2P, 3P, or 4P, matching a range of single and three-phase needs. Terminal connections offer screw type or busbar for added convenience.


Compliance and Long Service Life

Engineered in line with IEC 60947-2 standards, the DY 125U MCCB assures reliable operation with up to 10,000 mechanical and 5,000 electrical operations. Its durable construction and temperature protection features make it suitable for varying ambient conditions, reliably serving facilities across India.

FAQs of DY 125U MCCBs:


Q: How is the DY 125U MCCB installed in electrical panels?

A: The DY 125U MCCB can be installed either on a DIN rail or via fixed mounting, offering flexibility for panel builders. It features screw-type and busbar connection terminals, simplifying integration into different wiring schemes.

Q: What is the main advantage of the thermal magnetic trip type in this MCCB?

A: The thermal magnetic trip provides combined protection against both overloads and short circuits, enhancing safety and reliability by responding quickly to excessive currents, which helps in preventing equipment failures.

Q: Where can I source DY 125U MCCBs in India?

A: DY 125U MCCBs are available through authorized distributors, manufacturers, service providers, suppliers, traders, and wholesalers across India. You can contact your local electrical equipment supplier for purchase options.

Q: What is the process for selecting the correct DY 125U MCCB rating for my application?

A: To choose the appropriate MCCB, assess your load requirements, operating voltage (AC 400V), current (10A125A), number of phases, and desired breaking capacity. Refer to IEC 60947-2 guidelines and consult with your supplier for the best fit.

Q: When is it ideal to use DY 125U MCCBs in electrical installations?

A: These MCCBs are recommended for industrial and commercial settings needing reliable overload and short circuit protection, especially in environments requiring compliance with IEC standards and robust operational life.

Q: What is the operating temperature range of the DY 125U MCCB?

A: The DY 125U MCCB operates effectively in ambient temperatures ranging from -5C up to +40C, making it suitable for most indoor installations in Indias varied climate.

Q: What are the benefits of using DY 125U MCCBs for circuit protection?

A: Benefits include high breaking capacity, compliance with global safety standards, long operational life, flexible mounting options, and comprehensive protection for single or three-phase systems, reducing risks to property and personnel.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit Breaker Category

Mccb Single Pole 16a~160a

Mccb Single Pole 16a~160a

Price 360 INR

Minimum Order Quantity : AS PER DEMAND Piece

Color : Grey/White

Phase : Single Phase

Installation Options : Din Rail or Panel Mounted

Function : Overload and shortcircuit protection

Automatic Changeover With Current Limiter (ACCL)

Automatic Changeover With Current Limiter (ACCL)

Minimum Order Quantity : 20 Piece Pieces

Color : White and Grey

Phase : Single Phase

Installation Options : DIN Rail Mounting

Function : Automatic changeover between main supply and generator, current limiting

Mcb 2pole 6-63amp

Mcb 2pole 6-63amp

Color : White & Black

Phase : other, Single/Three Phase

Installation Options : DIN Rail Mounting

Function : Overload & Short Circuit Protection

Isolators / Mcb

Isolators / Mcb

Price 400 INR

Minimum Order Quantity : 20 Pieces

Color : White / Light Grey

Phase : other, Single Phase, Three Phase

Installation Options : DIN rail mounting

Function : Isolation and circuit protection