About MCCB With Microprocessor Release
Specification for dsine MTX1.0
Conforms to IS/IEC 60947-2
40A to 1250A, 3P & 4P
36kA, 50kA, 70kA and 100kA breaking capacities
Adjustable overload setting from 0.4 to 1.0 x In
Ics=100% Icu
Adjustable short-circuit setting from 1.5 to 8 x Ir
Inbuilt instantaneous Protection
Switchable thermal memory
Variable trip class
Front LED Indication
Manual, Rotary and Motorised versions available
Wide range of accessories
Specification for dsine-DZ iTRP1
Conforms to IS/IEC 60947-2
16A to 160A, 3P & 4P
36kA & 50kA breaking capacities
Ics=100% Icu
Adjustable overload setting from 0.25 to 1.0 x In
Adjustable short-circuit setting from 1.5 to 12 x Ir
OR Instantaneous setting from 1.5 to 12 x In
Switchable thermal memory
Variable trip class
Transparent sealable release cover
Compact size
Wide range of accessories
Specification for dsine MTX2.0
Conforms to IS/IEC 60947-2
Inbuilt ground fault protection from 20%-50% of In
40A to 1250A, 3P & 4P
Variable trip class
Panel mounted display for current metering & trip record
Adjustable overload setting from 0.4 to 1.0 x In
Adjustable neutral overload protection from 50% to 150% of Ir
Wide range of accessories
Inbuilt instantaneous Protection
Front LED Indication
Adjustable short-circuit setting from 1.5 to 8 x Ir
36kA, 50kA, 70kA and 100kA breaking capacities
Ics=100% Icu
Switchable thermal memory
Manual, Rotary and Motorised versions available
Specification for dsine-DZ iTRP3
Conforms to IS/IEC 60947-2
16A to 160A, 3P & 4P
36kA & 50kA breaking capacities
Ics=100% Icu
Adjustable overload setting from 0.25 to 1.0 x In
Adjustable short-circuit setting from 1.5 to 10 x Ir
Adjustable Instantaneous setting, 6 In & 12 In
Inbuilt ground fault protection from 20%-70% of In
Adjustable neutral overload protection from 50% to 200% of Ir
Switchable thermal memory
Provision for release testing
Individual fault indication LEDs
Transparent sealable release cover
Compact size
Wide range of accessories
Specification for MTX3.0
Conforms to IS/IEC 60947-2 & IEC 60947-2
Choice of 36kA / 50kA / 70kA / 100kA breaking capacities
Ics = 100% Icu
Suitable for Isolation
Adjustable Over Load from 0.4 - 1.0 x In
Adjustable Short Circuit from 1.5 - 8 x Ir with selectable time delay Instantaneous protection with fine settings
Range: 40A to 1250A, 3P & 4P
Manual, Rotary or Motorised versions available
Inbuilt ground fault protection from 10% - 50% of In
Advanced Current, Voltage, Frequency & Power based protections
Comprehensive Current, Power, Energy, PF, MD, THD metering
Variable trip class at 1.5 Ir,6 Ir & 7.2 Ir
Communication capable release
Other Protections like Maximum Demand, Phase Sequence, THD etc.
Provision of Thermal Memory : ON/OFF
Adjustable neutral overload protection available : 50% to 150% of Ir
Panel mounted display available for advanced protections & metering Front LED indication of Over Load, short circuit & earth fault
For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
Wide Range of snap fit Internal and External Accessories
Advanced Microprocessor ProtectionThe microprocessor release in this MCCB offers superior safety by swiftly responding to electrical faults, overloads, and short circuits. This digital technology enhances accuracy and reduces the risk of unwanted tripping, keeping your equipment safer and extending its operational life.
Easy Wall-Mounted InstallationUnlike traditional systems, this MCCB is designed for hassle-free wall mounting, streamlining the installation process. Its compact, white enclosure complements modern spaces and ensures quick access for maintenance, making it an excellent choice for a variety of Indian electrical setups.
FAQ's of MCCB With Microprocessor Release:
Q: How does the microprocessor release in this MCCB improve electrical safety?
A: The microprocessor release monitors electrical parameters in real time, enabling precise and rapid detection of abnormal conditions such as overloads or short circuits. This advanced system helps prevent electrical fires and equipment damage, providing enhanced protection compared to traditional mechanical systems.
Q: What installation options are available for this MCCB?
A: This MCCB is designed specifically for wall mounting, making it suitable for both new installations and retrofits. Its compact form factor allows it to be easily integrated into a range of single-phase, 220V setups.
Q: When should this MCCB be used in electrical systems?
A: This MCCB should be installed whenever you require reliable circuit protection for single-phase 220V installations, particularly when precise monitoring and quick response to electrical faults are critical for safety and equipment longevity.
Q: Where can this MCCB with microprocessor release be sourced in India?
A: It is available through multiple channels including distributors, manufacturers, service providers, suppliers, traders, and wholesalers throughout India, ensuring widespread accessibility for various types of projects and maintenance requirements.
Q: What is the process for installing the wall-mounted MCCB?
A: Installation involves securely fixing the MCCB onto a suitable wall surface, wiring it according to the single-phase, 220V electrical configuration, and configuring settings through the microprocessor interface. It's recommended to use a qualified electrician to ensure safety compliance.
Q: What are the benefits of using an MCCB with a microprocessor release?
A: Using a microprocessor-based MCCB ensures high-precision fault detection, minimizes risks of electrical hazards, enhances operational continuity, and usually requires less maintenance due to its advanced diagnostic capabilities.