Power Quality Solution
Power Quality Solution
Power Quality Solution
Power Quality Solution
Power Quality Solution
Power Quality Solution

Power Quality Solution

MOQ : 12 Pieces

Power Quality Solution Specification

  • Surface Finish
  • Powder Coated
  • Weight
  • Varies with configuration
  • Features
  • Automatic operation, real-time monitoring, LCD/LED display, energy saving, microcontroller-based
  • Usage & Applications
  • Power correction, harmonic filtering, industrial electrical systems, commercial buildings, renewable energy integration
  • Pole Type
  • Single & Three Phase
  • Mounting Type
  • Floor/Wall Mounted
  • Thickness
  • 1.6-2 mm (Enclosure)
  • Product Type
  • Automatic Power Factor Correction (APFC) Panel / Active Harmonic Filter
  • Material
  • Metal Cabinet with advanced electronic components
  • Rated Power
  • Customizable as per application
  • Length
  • Compact/Customizable
  • Voltage
  • 415V AC
  • Input Voltage
  • 230V/415V AC
  • Working Temperature
  • -10C to +55C
  • Rated Current
  • As per model specification
  • Socket
  • Terminal connections
  • Color
  • Grey/White
  • Height
  • Standard/Customizable
  • Protection Functions
  • Over/Under Voltage, Overload, Short Circuit, Over Temperature
  • Response Time
  • Fast response (<20ms)
  • Controller Type
  • Microprocessor/Microcontroller Based
  • Display
  • Digital LCD/LED Multifunction Meter
  • Capacitor Type
  • Heavy Duty Self-Healing Dry Type / APP / MPP
  • Communication Interface
  • RS485, Ethernet (Modbus) available
  • IP Rating
  • IP42 / IP54 / IP65
  • Frequency
  • 50Hz / 60Hz
  • Installation Location
  • Indoor / Outdoor (as per IP rating)
  • Cooling Type
  • Natural Air / Forced Cooling
 

Power Quality Solution Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • FOB Port
  • JAIPUR, NEEMRANA, ALWAR
  • Supply Ability
  • 5 Pieces Per Week
  • Delivery Time
  • 5-7 Week
  • Main Domestic Market
  • All India
  • Certifications
  • GST, GEM
 

About Power Quality Solution

Power Quality Solution

 

  • Longer, more productive life
  • Overcurrent wihstand: 1.6 x In
  • Peak inrush current withstand: 200 x In
  • Performs 6000 switching operation per year
  • Operating life - 115000 hrs

 



Advanced Monitoring and Fast Response

Experience superior control with cutting-edge microcontroller-based technology. This solution provides real-time power quality insights via digital LCD or LED multifunction meters. Leveraging RS485/Ethernet (Modbus) interfaces, it ensures seamless integration with existing energy management systems and enables a fast corrective action with a response time of less than 20 milliseconds.


Robust Protection and Reliability

Enhance equipment safety with a suite of built-in protective functions: over and under voltage, overload, short circuit, and over temperature detection. Its self-healing dry or APP/MPP capacitors paired with natural or forced cooling increase longevity and performance.


Flexible Application and Installation

Suitable for a wide range of environments-including industrial and commercial electrical systems, renewable energy sites, and utility panels. The enclosure, made from metal with a powder-coated finish and customizable dimensions, supports both indoor and outdoor mounting (IP42/IP54/IP65), and is available in a range of standard or tailored sizes.

FAQ's of Power Quality Solution:


Q: How does the microprocessor/microcontroller-based controller improve power quality management?

A: The controller provides precise, automated real-time monitoring and correction of power parameters. Its fast response (<20ms) ensures quick mitigation of power disturbances and effective harmonic filtering, optimizing system reliability and efficiency.

Q: What communication interfaces are available for system integration?

A: The solution supports both RS485 and Ethernet (Modbus) interfaces, facilitating seamless communication and easy integration with building management systems or SCADA platforms for remote monitoring and control.

Q: When should I use forced cooling instead of natural air cooling?

A: Forced cooling is recommended in high-load applications or warmer environments where greater heat dissipation is necessary to maintain optimal system performance and protect electronic components from overheating.

Q: Where can this Power Quality Solution be installed?

A: It can be installed indoors or outdoors, depending on the chosen IP rating (IP42, IP54, IP65). Its enclosure design and mounting options (floor/wall) make it adaptable to different spaces, ensuring protection against dust, moisture, and weather conditions as required.

Q: What is the typical process for installation and commissioning?

A: Installation involves mounting the metal cabinet, connecting terminal inputs/outputs as per the wiring diagram, and configuring settings via the digital LCD/LED meter. The system automatically calibrates key parameters after initial power-up, making commissioning straightforward.

Q: How does the heavy-duty self-healing capacitor enhance system reliability?

A: Self-healing capacitors automatically repair minor dielectric breakdowns, maintaining their performance and increasing their lifespan. This reduces maintenance needs and downtime, ensuring consistent power quality over time.

Q: What are the main benefits of using this solution in industrial and commercial applications?

A: The solution delivers improved power factor correction, harmonic filtering, robust electrical protection, and energy savings. It ensures compliance with stringent operational standards, prolongs equipment life, and enhances productivity for users in a broad range of sectors.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Low Voltage Switchgears Category

FN-TPN S-D-F Suitable for BS Fuse Link

FN-TPN S-D-F Suitable for BS Fuse Link

Voltage : Up to 415V AC

Rated Current : Up to 100A (as per fuse link selection)

Usage & Applications : Suitable for industrial and commercial fuse installations

Features : Shock proof, flame retardant, easy fuse replacement, secure terminal connections

Working Temperature : 10C to +55C

Surface Finish : Smooth, insulating and nonconductive finish

Active Harmonic Filter (AHF)

Active Harmonic Filter (AHF)

Voltage : 380V/400V/415V AC

Rated Current : 30A to 1200A

Usage & Applications : Power quality improvement, harmonic filtering, commercial & industrial electrical systems

Features : Realtime harmonic compensation, dynamic filtering, microprocessor control, LCD display

Working Temperature : 10C to +45C

Surface Finish : Epoxy powdercoated

CONTECTOR 4POLE 25A~125A

CONTECTOR 4POLE 25A~125A

Voltage : 415 V AC

Rated Current : 25A, 32A, 63A, 100A, 125A (as per model)

Usage & Applications : Industrial electrical connections, control panels, heavy machinery, power distribution

Features : Flame resistant, shock proof, high conductivity

Working Temperature : 10C to +60C

Surface Finish : Polished/Bakelite finish

RCCB 4POLE 10-100AMP

RCCB 4POLE 10-100AMP

Voltage : 230/415V AC

Rated Current : 10A to 100A selectable

Usage & Applications : Protection against earth leakage and electric shock in residential, commercial, and industrial installations

Features : Tripfree mechanism, double break contacts, high sensitivity to leakage current, test button for functional check, compact design

Working Temperature : 5C to 40C

Surface Finish : Matte / Smooth Finish



Back to top