RCCB 1
RCCB 1
RCCB 1
RCCB 1

RCCB 1

MOQ : 20 Pieces

RCCB 1 Specification

  • Mechanical Life
  • 10,000 Operations
  • Rated Short Circuit Breaking Current
  • 6000A
  • Breaking Capacity
  • 6 kA
  • Phase
  • Single Phase / Three Phase
  • Rated Short Circuit Making Current
  • 6000A
  • Product Type
  • RCCB (Residual Current Circuit Breaker)
  • Installation Options
  • DIN Rail Mounting
  • Function
  • Earth Leakage Protection (Residual Current Protection)
  • Poles Number
  • 2P (Double Pole)
  • Rated Voltage
  • 230V / 415V AC
  • Rated Current
  • 25A, 40A, 63A
  • Rated Frequency
  • 50 Hz
  • Curves
  • Type AC
  • Temperature Protection
  • -5C to +40C
  • Weight
  • approx. 250g
  • Color
  • White & Grey
  • Terminal Capacity
  • 16 sq.mm Max
  • Housing Material
  • High Grade Flame Retardant Plastic
  • Operating Voltage Range
  • 180V - 264V AC (per pole)
  • Trip Indicator
  • Yes (Visual Indicator)
  • IP Protection Degree
  • IP20
  • Standards Compliance
  • IS 12640/IEC 61008
  • Rated Insulation Voltage
  • 690V AC
  • Mounting Type
  • Snap-on DIN Rail
  • Sensitivity (Rated Residual Operating Current)
  • 30mA, 100mA, 300mA
 

RCCB 1 Trade Information

  • Minimum Order Quantity
  • 20 Pieces
  • FOB Port
  • Jaipur,Neemrana,Alwar
  • Payment Terms
  • Cash on Delivery (COD), Telegraphic Transfer (T/T), Cheque, Cash Advance (CA)
  • Supply Ability
  • Piece
  • Delivery Time
  • 5-7 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Domestic Market
  • All India
  • Certifications
  • GEM,GST
 

About RCCB 1

We take pride in manufacturing and supplying a wide range of Residual Current Circuit Breakers. The product is developed precisely under the proper guidance of experts and professionals having umpteen years of experience. The products we offer are of high quality and easily available in the market at reasonable rates. Residual Current Circuit Breakers are further plated with mild steel and are highly acknowledged for their durability.

Features:

  • Compact design

  • Saves energy

  • Longer service life



Reliable Earth Leakage Protection

RCCB 1 ensures the highest level of safety for electrical circuits by disconnecting power promptly when earth leakage occurs. With multiple sensitivity options30mA for personal protection, 100mA and 300mA for equipment and fire preventionthe RCCB is engineered for diverse environments, ensuring compliance with IS 12640 and IEC 61008 standards. Its sturdy design and comprehensive protection make it a suitable choice for homes, offices, and industrial setups.


Robust Design and Easy Installation

Crafted with high-grade flame-retardant plastic, RCCB 1 boasts an IP20 protection degree, safeguarding against dust and accidental contact. The device can be securely mounted using its snap-on DIN rail mechanism, supporting terminal capacities up to 16 sq.mm for versatile wiring. The clear visual trip indicator provides immediate status updates, promoting swift maintenance and operational efficiency.


Versatility for Indian Electrical Systems

RCCB 1 is tailored for the Indian market, supporting both single-phase and three-phase systems at rated voltages of 230V/415V AC and a frequency of 50 Hz. With breaking and making capacities of 6000A, it ensures durability and high performance in various operational settings. The device can withstand extreme temperatures from -5C to +40C and offers a mechanical life of up to 10,000 operations, making it reliable for long-term use.

FAQs of RCCB 1:


Q: How does RCCB 1 provide earth leakage protection?

A: RCCB 1 monitors the difference between the live and neutral currents in a circuit. If a leakage or imbalance above the rated sensitivity (30/100/300mA) is detected, it instantly disconnects the power, preventing electric shocks or fire hazards, thereby ensuring personnel and equipment safety.

Q: What types of installations is RCCB 1 suitable for in India?

A: RCCB 1 is versatile, supporting both single-phase and three-phase electrical systems. Its snap-on DIN rail mounting, robust build, and compliance with IS 12640/IEC 61008 make it ideal for residential, commercial, and industrial installations throughout India.

Q: When should I choose between 30mA, 100mA, and 300mA sensitivity options?

A: Select 30mA sensitivity for personal protection against electric shock, 100mA for enhanced protection where higher leakage currents are expected, and 300mA for equipment or fire prevention. The choice depends on your installations safety requirements and regulatory guidelines.

Q: Where can RCCB 1 be installed within an electrical panel?

A: RCCB 1 is designed for installation on standard DIN rails within electrical distribution panels. Its snap-on mechanism makes setup quick and straightforward, ensuring secure placement alongside other circuit protection devices.

Q: What is the installation process for RCCB 1?

A: To install RCCB 1, snap it onto the DIN rail inside your panel, connect the incoming and outgoing wires (up to 16 sq.mm terminal capacity), and ensure all connections are properly tightened. Always comply with safety standards and, if required, consult a qualified electrician.

Q: How do I benefit from the RCCB 1s visual trip indicator?

A: The visual trip indicator immediately displays the operational status of the device. In case of a residual current fault and subsequent tripping, the indicator enables quick identification, reducing downtime and facilitating prompt maintenance.

Q: What are the usage and service life benefits of RCCB 1?

A: RCCB 1 offers a long mechanical life of up to 10,000 operations, withstands high breaking/making currents up to 6000A, and endures temperatures from -5C to +40C. This durability ensures prolonged protection and reliable performance in demanding environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit Breaker Category

Moter protection circuit Breakers

Moter protection circuit Breakers

Price 1995 INR

Minimum Order Quantity : 20 Pieces

Phase : other, Threephase

Product Type : Other, Motor Protection Circuit Breaker

Rated Voltage : AC 400V/415V

Rated Frequency : 50/60 Hz

Mccb Single Pole 16a~160a

Mccb Single Pole 16a~160a

Price 360 INR

Minimum Order Quantity : AS PER DEMAND Piece

Phase : Single Phase

Product Type : Other, Moulded Case Circuit Breaker (MCCB)

Rated Voltage : AC 400V / 415V

Rated Frequency : 50/60 Hz

SURGE PROTECTION DEVICE

SURGE PROTECTION DEVICE

Price 10800 INR

Minimum Order Quantity : 20 Pieces

Phase : other, 3 Phase + Neutral

Product Type : Other, Surge Protection Device (SPD)

Rated Voltage : 230/400 V AC

Rated Frequency : 50/60 Hz

Mcb Single Pole 6-63amp

Mcb Single Pole 6-63amp

Price 400 INR / Piece

Minimum Order Quantity : 20 Pieces

Phase : other, Single

Product Type : Mini

Rated Voltage : 220 Volt(v)

Rated Frequency : 50/60 Hertz(Hz)



Back to top