MCCB 4 POLE 63A-400A Specification

  • Phase
  • Three Phase
  • Mechanical Life
  • Up to 10,000 Operations
  • Rated Short Circuit Making Current
  • Icm: Up to 100 kA
  • Rated Short Circuit Breaking Current
  • Icu: Up to 50 kA
  • Breaking Capacity
  • 25 kA to 50 kA
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mount, DIN Rail Mount
  • Function
  • Overcurrent, Short Circuit and Overload Protection
  • Poles Number
  • 4 Poles
  • Rated Voltage
  • 415V AC
  • Rated Current
  • 63A - 400A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • C, D Types
  • Temperature Protection
  • Thermal and Magnetic Trip Units
  • Weight
  • Approx. 3.5 kg
  • Color
  • Grey/Black
  • Insulation Voltage
  • 800V
  • Rated Impulse Withstand Voltage (Uimp)
  • 8 kV
  • Operating Temperature Range
  • -5C to +55C
  • Contact Position Indicator
  • Yes
  • Protection Degree
  • IP20
  • Terminal Type
  • Screw Terminals
  • Trip Unit Type
  • Fixed and Adjustable
  • Auxiliary Contacts
  • Available on request
  • Ambient Compensation
  • Yes
  • Mounting Position
  • Vertical, Horizontal
 

MCCB 4 POLE 63A-400A Trade Information

  • FOB Port
  • JAIPUR
  • Payment Terms
  • Cash on Delivery (COD), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque
  • Delivery Time
  • 7 Days
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • STANDARD
  • Main Domestic Market
  • All India
  • Certifications
  • GEM&GST
 

About MCCB 4 POLE 63A-400A

Conforms to IS/IES 60947-2

 

ICS=100% Icu

Range: 63A-400A 4POLE

Breaking capacity: 25kA, 35/36kA, 50kA

 

Positive isolation

Trip free mechanism

 

Neutral with 100% rated current 

Bounce free contact structure

 

Wide range of internal & External Accessories

 

SS Enclosure available

 

Standard packing includes insulating phase barrier and hardware



Advanced Protection for Demanding Applications

Designed for high-reliability performance, this MCCB offers both overcurrent and short-circuit protection, ensuring maximum safety for your electrical systems. The combination of thermal and magnetic trip units allows precise response to potential hazards, while adjustable and fixed trip options provide flexibility to match your installations requirements. Its rated short circuit breaking and making capacity deliver confidence even in high-energy fault conditions.


Flexible Mounting and Installation Options

Supporting both panel mount and DIN rail mount installations, this MCCB adapts to a variety of environments and panel designs. Screw-type terminals facilitate secure and straightforward connections. The compact 4-pole configuration, ambient temperature compensation, and robust construction (grey/black color, approx. 3.5 kg) add to its suitability for demanding industrial and infrastructure projects.


Operational Safety and User Feedback

A contact position indicator keeps operators informed about switching status, enhancing both safety and diagnostics. The IP20 degree of protection safeguards users against accidental contact, while mechanical life of up to 10,000 operations ensures long-term reliability. Auxiliary contacts can be added upon request, expanding monitoring and automation possibilities for advanced control requirements.

FAQs of MCCB 4 POLE 63A-400A:


Q: How does the MCCB 4 Pole 63A-400A protect electrical systems?

A: This MCCB provides comprehensive protection against overcurrent, short circuit, and overload conditions using advanced thermal and magnetic trip units. It interrupts dangerous fault currents quickly, minimizing equipment damage and enhancing overall system safety.

Q: What installation options are available for this MCCB?

A: The device supports both panel mount and DIN rail mounting, offering flexibility for integration into new projects or existing systems. Screw terminals allow for easy and secure cable connections during installation.

Q: When should I choose the fixed or adjustable trip unit type?

A: Fixed trip units are ideal for standard applications requiring consistent protection settings. Adjustable trip units are recommended when you need to tailor protection thresholds for specific loads or operational scenarios, offering greater flexibility in system design.

Q: Where can the MCCB be used considering its temperature range and protection degree?

A: With an operating temperature range of -5C to +55C and IP20 protection degree, the MCCB is well-suited for most indoor industrial and commercial environments across India. It should be installed in locations free from excessive dust, moisture, or corrosive atmospheres for optimal performance.

Q: What is the process to request auxiliary contacts for this MCCB?

A: Auxiliary contacts are available upon request. When placing your order through a distributor or manufacturer, specify the need for auxiliary contacts to ensure they are included with your MCCB for extended functionality and integration into automation or monitoring systems.

Q: How does ambient compensation benefit the MCCBs operation?

A: Ambient compensation ensures the MCCB delivers accurate protection regardless of temperature variations within the specified range, preventing unnecessary tripping or under-protection in fluctuating environments.

Q: What are the main usage benefits of this 4-pole MCCB?

A: The main benefits include reliable three-phase circuit protection, adaptability for varied electrical loads, easy installation, high breaking capacity, and operational longevitymaking it ideal for industrial, manufacturing, and infrastructure projects throughout India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit Breaker Category

Residual Current Circuit Breaker (RCCB)

Residual Current Circuit Breaker (RCCB)

Price 2500 INR / Piece

Minimum Order Quantity : 5 Pieces

Function : Protection against earth leakage & electric shock

Phase : other, Single Phase/Three Phase

Rated Frequency : 50 Hz

Installation Options : DIN rail mounting

RCCB 1

RCCB 1

Price 2405 INR

Minimum Order Quantity : 20 Pieces

Function : Earth Leakage Protection (Residual Current Protection)

Phase : other, Single Phase / Three Phase

Rated Frequency : 50 Hz

Installation Options : DIN Rail Mounting

Isolators / Mcb

Isolators / Mcb

Price 400 INR

Minimum Order Quantity : 20 Pieces

Function : Isolation and circuit protection

Phase : other, Single Phase, Three Phase

Rated Frequency : 50 Hz/60 Hz

Installation Options : DIN rail mounting

SURGE PROTECTION DEVICE

SURGE PROTECTION DEVICE

Price 10800 INR

Minimum Order Quantity : 20 Pieces

Function : Protects electrical installations from transient overvoltages

Phase : other, 3 Phase + Neutral

Rated Frequency : 50/60 Hz

Installation Options : DIN Rail Mounted



Back to top